Requirements for LongLink™ LPS
-
LongLink™ capability, achieved in one of two ways:
- 1014464-03, SL-R4 LongLink™ Module Upgrade.
- 1006146-10, MC-i4 Global SL-R4+LongLink™.
- PS/AS Total Station and prism.
PS/AS Configuration
- Press (PRG) on the keypad.
- Navigate to the Info Screen.
- Press Config to bring up the configurations menu.
-
Press 4.EDM and confugre as follows:
- Dist. Mode: Tracking
- Reflector: Prism.
- Prism Const: 2mm
- Press OK

- Press 5.Comms.
-
From the Comms Setup tab, configure as follows:
- Comms Module: Bluetooth.
- Checksum: Yes.
- Controller: 2 Way+Remote.
- Rec Tybe: B.
- Terminate: EXT+CR.
- TRK State: On.
- ACK Mode: Off

-
Press the Bluetooth tab and configre as follows:
- Mode: Slave.
- Autentication: Yes or No. (Yes if passkey entered. Must match 3D-MC)
- Passkey: Must match 3D-MC.
- Press the Info tab and copy the BD ADDR. This number is the MAC address 3D-MC will need to establish a connection.
- Press OK.

- Press 9.Motor.
-
From the Configuration tab, configure as follows:
- Auto Atim: Rapid.
- MEAS Acc: Standard.
- Track Setting: Track.
- Srch method: G.S.
- Press OK.

Start LPS Control
- Navigate to LPS Setup on the PS/AS.
- Press Setup Units to select unit system.
-
Press Setup File.
- New will create a new job.
- Points lets you manually enter the contol points.
- Save As will save the current project.
- Copy will let you import a *.GC3 from Pocket3D or 3D-MC.

- Press Station Setup Wizard.
-
Choose Setup Method:
- Known Station and Backsight Point.
- Known Station and Azimuth.
- New Station by Resection.
- Start LPS Control.
- Put PS/AS in External Link mode.

3D-MC Configuration
- Set sensor type to Prism.

-
Set Position Input to MC-R3 (LongLink™)
- If using MC-i4 for LPS excavator, select MC-i4 (LongLink™).

- Enter MAC Address.
- If no passkey is required, it defaults to 0000.